Home > Altiris Deployment > Altiris Deployment Solution Error 1618

Altiris Deployment Solution Error 1618

Contents

Answered 01/29/2010 by: aslander Please log in to comment Please log in to comment 0 Not much luck, it works fine from the command line. Is there any way to ensure that the installation is completed entirely before starting the next step in the task sequence? Toggle navigation Software Tips Questions Blogs Links Communities Questions & Answers OSD: Error 1618 During Task Sequence OSD: Error 1618 During Task Sequence aslander How helpful is this to you? I am using: msiexec.exe /i owc11.msi /qn this works fine when I try it from command prompt on a test system, but fails during the task sequence with the following error: Source

ERROR_SUCCESS_REBOOT_REQUIREDd Article Filed Under: Endpoint Management, Wise Packaging, Configuring Login or register to post comments Comments RSS Feed Comments 2 Comments • Jump to latest comment WiseUser Windows Installer Exit / Please check the status of this program to determine whether or not it was completed sucessfully Possible causes: The version of Windows Installer on the computer is less than version 2.0, ERROR_PRODUCT_VERSION 1639 Invalid command line argument. I have been playing tag with this, because every time I fix one, it seems that other ones start happening in a day or two. http://www.symantec.com/connect/forums/errors-1618-and-1619-when-upgrade-altiris-agent-7-plug-ins

Altiris Deployment Solution Download

This error means that you have more than one instance of Windows Installer running and so the process cannot continue. Press 'Retry' when the install is finished or 'Cancel' to cancel setup.' The setup then cancels, tries to rollback itself, but fails doing that with the same "The uninstallation appears to I even had task manager going in the background to detect new services installing and still no go. It can look something like this: MSI (c) (B8:50) [12:43:49:297]: MainEngineThread is returning 1601 Number Description Error Code 0 Completed Successfully.

ERROR_DATATYPE_MISMATCH 1630 Data of this type is not supported. ERROR_INSTALL_TEMP_UNWRITABLE 1633 This installation package is not supported on this platform. ERROR_UNKNOWN_COMPONENT 1608 Unknown property. Altiris Deployment Solution Alternative How To Fix Error Code 1618 Step 1 - Make Sure You Only Have One Instance Of Windows Installer Running Having multiple Windows Installer processes can cause the application itself to

If Windows Installer determines a product may be incompatible with the current operating system, it displays a dialog informing the user and asking whether to try to install anyway. Press 'Retry' when the install is finished or 'Cancel' to cancel setup.' Message returned: 2 Error: User canceled install due to MSI service being busy. ERROR_INSTALL_PACKAGE_INVALIDd 1621 There was an error starting the Windows Installer service user interface. http://jacobsalmela.com/altiris-fix-error-1618-another-installation-is-already-in-progress/ ERROR_UNKNOWN_PROPERTY 1609 Handle is in an invalid state.

The registry is a database inside the Windows system which stores important settings & options for your PC. Altiris Deployment Solution 7.1 User Guide ERROR_INVALID_TABLE 1629 Data supplied is of wrong type. I have issues with getting errors during specific package installations, and it gives Error 1618: Installation is already in progress on the next step in the sequence. These may be in the task bar or, if there is a setup running in the background, in task manager.

Altiris Deployment Solution 6.9 Sp5 Download

ERROR_INVALID_FIELD 1618 Another installation is already in progress. http://www.altirigos.com/forums/threads/agent-install-error-1618-another-install-in-progress.13104/ Learn More Ghost Solution Suite 3.0 - "How-to" Videos We have created several "How To" videos and posted links on this page. Altiris Deployment Solution Download Thanks. Altiris Deployment Solution Vs Sccm All rights reserved.Newsletter|Contact Us|Privacy Statement|Terms of Use|Trademarks|Site Feedback TechNet Products IT Resources Downloads Training Support Products Windows Windows Server System Center Browser   Office Office 365 Exchange Server   SQL Server

ERROR_INSTALL_TRANSFORM_REJECTED 3010 A reboot is required to complete the install. this contact form Privacy statement  © 2016 Microsoft. During the installation of Office, this started its auto-update cycle to the latest version. A mention of SEP in the Office setup.exe log, was what put me on track. Altiris Deployment Solution 7.1 Training

I'm seeing the same behavior during my TS, which used to run just fine. Contact the application vendor to verify that this is a valid Windows Installer package. It sounds like OWC is defaulting to looking for a user account to install from, ALLUSERS=1 should take care of that. have a peek here Related Author: Jacob Salmela I am introverted.

I'll keep you guys posted, thanks for the help so far! Altiris Deployment Solution 7.5 Training SCCM only tracks the executable you have specified on the command line, so once the owc11.exe ends, SCCM thinks that the program is complete. Answered 02/15/2012 by: Ksuekihlman Please log in to comment Please log in to comment 0 use of ALLUSERS=1in an msiexec command line to elevate user privileges Tootle on over to MSDN/TechNet

ERROR_INSTALL_PLATFORM_UNSUPPORTED 1634 Component not used on this machine ERROR_INSTALL_NOTUSED 1635 This patch package could not be opened.

Friday, January 20, 2012 1:18 PM Reply | Quote All replies 0 Sign in to vote Some more things that I did in the meantime: - Disabled the Antivirus, no effect Thanks Answered 02/01/2010 by: aslander Please log in to comment Please log in to comment 0 I was intrigued by your use of ALLUSERS=1in an msiexec command line to elevate user I made a package out of Office 2010 with SP1 integrated, and am deploying it with the command line setup /adminfile c:\x\upgrade.msp /config c:\x\upgrade.xml SCCM is configured to download packages to Altiris Deployment Solution 7.5 Installation Guide I'm not 100% certain on OWC, but I do know that many other (poorly designed) programs behave this way.

After that, Office is upgraded and works. Not many people realize it, but this could be the reason why the 1618 error is appearing. » Download Windows Repair Tool Highly Recommended This is our recommended cleaning tool that ERROR_UNSUPPORTED_TYPE 1631 The Windows Installer service failed to start. Check This Out ERROR_INVALID_COMMAND_LINE 1640 Installation from a Terminal Server client session not permitted for current user.

Posted on August 8th, 2008 . So basically, I have one step in the sequence complete successfully (according to the log): The task sequence execution engine successfully completed the action (Office Web Components 11) in the group Is there a way to prevent this? Now the awkward thing is that all my other applications installs just fine.

I have a VM which I snapshotted before the deployment. This will arise when Windows Installer has more than one instance running. In the past I have separated out the current user settings and applied them “as the logged on user”, but of course, this is a pain, so I’m hoping this an One lucky winner will receive 500 Connect points! * Take the survey.

After this happened the first time, I changed the installation so that the PCs would always do a reboot before the installation, but this didn't help anything. Solving this problem is quite simple, you will either have to end the other Windows Installer process or if the problem does not subside then carry out a registry scan with altiris-error-codes.xls -------------------------------------- Tags: Altiris, error, error codes, spreadsheet, xls Filed under Altiris | 8 Responses to "Altiris Error Codes" Jim Says: August 9th, 2008 at 4:05 am really useful, thanks Chris This error is not that hard to avoid but does require a certain level of knowledge.

Two Windows Installer procedures cannot be run at the same time, it has not been designed for that.